PZH R3 C/S

Code: 7732007

PZH R3 C/S

Code: 7732007

Surge arresters type T3 intended for use in installation and floor boxes and cable trays. Additional protection of socket circuits supplying devices with sensitive electronics. Additional protection of industrial socket circuits equipped with surge protection and a high-frequency filter (PZH HF, PZH HF3). Installed at the boundaries of LPZ 2 – LPZ 3, as close as possible to the protected device (no further than 5 m). In front of PZH R3 C/S must be installed a lightning current and surge arrester T1 and T2 from HERMI company. The protection devices offer a high discharge capacity in the surge arrester category T3, with UOC 6 kV / In 3 kA. Application standards: IEC 62305:2010, HD 60364-5-53:2022, CLC/TS 61643-12:2009.

TECHNISCHE DATEN UND NORMEN

IM KATALOG VERWENDETE KENNZEICHNUNGEN

MATERIALIEN


KENNZEICHNUNG
MATERIAL
Rf
rostfreier Stahl
Rf*H4
säurebeständiger Edelstahl
Cu
Kupfer
Al
Aluminium
Fe
Stahl
FeZn
verzinkter Stahl
FeZn-H
feuerverzinkter Stahl
KFe
gehärteter Stahl
FeCu
verkupferter Stahl
Me
Messing
PE
Polyethylen – UV-stabil
N
Nylon – UV-stabil
P-SV
UV-verstärkter Polyester
pvc
elektrostatisch plastifiziert
PVC
widerstandsfähiger Kunststoff
Holz
Holz
Beton
Beton
Gus
Gusseisen
CuSn
verzinntes Kupfer
PP
Polypropylen

ABMESSUNGEN DES LEITERS

(Eignung der Träger für ein bestimmtes Leiterprofil)

KENNZEICHNUNG
BEDEUTUNG
Φ

Durchmesser des Rundleiters

P

Querschnittsabmessungen des Flachleiters


DRAHTKONDITIONSSYSTEM UND HALTERUNG

KENNZEICHNUNG
BEDEUTUNG
N

Befestigung mit Nylonverschluss

PE

Befestigung mit Polyäthylenverschluss

K
Befestigung mit Klicksystem
V
Befestigung durch Schrauben
*
benutzerdefiniert
Legende der Symbole

Surge arresters type T3 intended for use in installation and floor boxes and cable trays. Additional protection of socket circuits supplying devices with sensitive electronics. Additional protection of industrial socket circuits equipped with surge protection and a high-frequency filter (PZH HF, PZH HF3). Installed at the boundaries of LPZ 2 – LPZ 3, as close as possible to the protected device (no further than 5 m). In front of PZH R3 C/S must be installed a lightning current and surge arrester T1 and T2 from HERMI company. The protection devices offer a high discharge capacity in the surge arrester category T3, with UOC 6 kV / In 3 kA. Application standards: IEC 62305:2010, HD 60364-5-53:2022, CLC/TS 61643-12:2009.

There are currenty no files for your language.

Name der Webseite

Kontakt

Hermi, d.o.o.

Trnoveljska cesta 15

3000 Celje

Slowenien