PZH R3 HF 16/220VDC

Code: 7730148

PZH R3 HF 16/220VDC

Code: 7730148

PZH R3 HSAF16/*VDC is a surge arrester with integrated high-frequency filter designed for DC power supply systems. PZH R3 HSAF16/*VDC contains an improved thermal fuse which ensures timely disconnection of the device from the power grid during overheating and thus prevents damage to the PZH R3 HSAF16/*VDC. Activation of the thermal fuse is signalled by an integral indicator light. The PZH R3 HSAF16/*VDC is a type T3 two-port surge arrester and has been tested according to standards EN 61643-11 (IEC 61643-11:2011). According to standard EN 62305 (IEC 62305:2010), it is installed in the boundary between zones LPZ 2 - LPZ 3, where it limits induced overvoltage and residual overvoltage in power lines. PZH R3 HSAF16/*VDC are designed to be mounted on a 35 mm DIN rail using a metal clip. Manufacturer’s recommendation: Install the PZH R3 HSAF16/*VDC as close to the device to be protected as possible (no further than 5 m). There must be Hermi’s lightning and surge arrester T1 and T2 installed before the PZH R3 HSAF16/*VDC

TECHNISCHE DATEN UND NORMEN

IM KATALOG VERWENDETE KENNZEICHNUNGEN

MATERIALIEN


KENNZEICHNUNG
MATERIAL
Rf
rostfreier Stahl
Rf*H4
säurebeständiger Edelstahl
Cu
Kupfer
Al
Aluminium
Fe
Stahl
FeZn
verzinkter Stahl
FeZn-H
feuerverzinkter Stahl
KFe
gehärteter Stahl
FeCu
verkupferter Stahl
Me
Messing
PE
Polyethylen – UV-stabil
N
Nylon – UV-stabil
P-SV
UV-verstärkter Polyester
pvc
elektrostatisch plastifiziert
PVC
widerstandsfähiger Kunststoff
Holz
Holz
Beton
Beton
Gus
Gusseisen
CuSn
verzinntes Kupfer
PP
Polypropylen

ABMESSUNGEN DES LEITERS

(Eignung der Träger für ein bestimmtes Leiterprofil)

KENNZEICHNUNG
BEDEUTUNG
Φ

Durchmesser des Rundleiters

P

Querschnittsabmessungen des Flachleiters


DRAHTKONDITIONSSYSTEM UND HALTERUNG

KENNZEICHNUNG
BEDEUTUNG
N

Befestigung mit Nylonverschluss

PE

Befestigung mit Polyäthylenverschluss

K
Befestigung mit Klicksystem
V
Befestigung durch Schrauben
*
benutzerdefiniert
Legende der Symbole
PZH R3 HSAF16/*VDC is a surge arrester with integrated high-frequency filter designed for DC power supply systems. PZH R3 HSAF16/*VDC contains an improved thermal fuse which ensures timely disconnection of the device from the power grid during overheating and thus prevents damage to the PZH R3 HSAF16/*VDC. Activation of the thermal fuse is signalled by an integral indicator light. The PZH R3 HSAF16/*VDC is a type T3 two-port surge arrester and has been tested according to standards EN 61643-11 (IEC 61643-11:2011). According to standard EN 62305 (IEC 62305:2010), it is installed in the boundary between zones LPZ 2 - LPZ 3, where it limits induced overvoltage and residual overvoltage in power lines. PZH R3 HSAF16/*VDC are designed to be mounted on a 35 mm DIN rail using a metal clip. Manufacturer’s recommendation: Install the PZH R3 HSAF16/*VDC as close to the device to be protected as possible (no further than 5 m). There must be Hermi’s lightning and surge arrester T1 and T2 installed before the PZH R3 HSAF16/*VDC
Montageart DIN rail (top hat rail) 35 mm
ISO9001_&_ISO14001_de.pdf
Name der Webseite

Kontakt

Hermi, d.o.o.

Trnoveljska cesta 15

3000 Celje

Slowenien